    LD-560 HbA1c Test Analyzer HPLC Method High Correlation NGSP Certificated

    Ask Lasest Price
    Brand Name : LABNOVATION
    Model Number : LD-560
    Certification : IFCC, NGSP, CE
    Price : US$5000-12000/Piece
    Payment Terms : D/A, D/P, T/T
    Supply Ability : 100 Units/Day
    Delivery Time : 5-7 work day
    • Product Details
    • Company Profile

    LD-560 HbA1c Test Analyzer HPLC Method High Correlation NGSP Certificated

    Analyzer LD-560 HbA1c Analyzer Best Performance HPLC Method High Correlation NGSP Certificated


    Intended Use

    The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.


    LD-560 HbA1c Test Analyzer HPLC Method High Correlation NGSP Certificated


    Performance Parameteras


    • Reporting unit: Glycosylated hemoglobin (HbA1c) is reported in NGSP (%) and IFCC units (mmol/mol).
    • Accuracy: The accuracy is tested with reference materials as samples, and the relative deviation of the
    • test results should be within ± 5%.
    • Repeatability: For samples with a test concentration of 4% 6%, the sample coefficient of variation (CV)
    • of the test results is not greater than 2.0%.
    • Linear range: Within the range of 3% 18% of glycosylated hemoglobin, the linear correlation coefficien t
    • R value of the test results should not be less than 0.9900.
    • Stability: Within 8 hours after the analyzer is turned on and stabilized, the same normal sample is tested, and the relative deviation of the test results is not more than ±3.0%.
    • Carrying pollution: The carrying pollution rate of the analyzer should not be greater than 2.0%.
    • Basic function: Provides Chinese report and abnormal alarm.
    • The temperature accuracy and fluctuation of the chromatography column module: the temperature is within ±1°C of the set value, and the fluctuation is not more than 0.8°C.

    Specifications

    NameFully Automated HbA1c Analyzer
    ModelLD-560
    MethodHPLC
    ParametersHbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional)
    Test Speed90 seconds per test
    Wavelength420nm
    Sample TypeWhole Blood, Pre-diluted blood
    Autoloader Capacity20 tubes
    Reagents KitEluent A, Eluen B, Hemolysis, Chromatography Column
    PrecisionCV<2%
    Column Capacity3000 tests
    Report Range3-18%
    Working ConditionTemperature: 15-30℃
    Voltage100-240V
    Dimensions378mm×380mm×510mm

    Reagents and Consumables

    • Eluent A/Eluent B/Eluent C(Variant Mode)
    • Hemolysis Reagent H
    • Chromatography Column
    • Column Filte r
    • Paper Rolls

    Full automatic smart system


    • One click start testing
    • Automatic sample type recognition
    • Automatic testing mode switch
    • Automatic scanning of barcode
    • Autoloader for 20 tubes
    • Easy to change reagents

    Certificate

    LD-560 HbA1c Test Analyzer HPLC Method High Correlation NGSP Certificated


    LD-560 HbA1c Test Analyzer HPLC Method High Correlation NGSP Certificated


    Quality LD-560 HbA1c Test Analyzer HPLC Method High Correlation NGSP Certificated for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Labnovation Technologies, Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)