Fasting Diagnostic HPLC HbA1c Analyzer Fully Automated 5uL In Whole Blood Mode

    Buy cheap Fasting Diagnostic HPLC HbA1c Analyzer Fully Automated 5uL In Whole Blood Mode from wholesalers
     
    Buy cheap Fasting Diagnostic HPLC HbA1c Analyzer Fully Automated 5uL In Whole Blood Mode from wholesalers
    • Buy cheap Fasting Diagnostic HPLC HbA1c Analyzer Fully Automated 5uL In Whole Blood Mode from wholesalers

    Fasting Diagnostic HPLC HbA1c Analyzer Fully Automated 5uL In Whole Blood Mode

    Ask Lasest Price
    Brand Name : LABNOVATION
    Model Number : LD-560
    Certification : IFCC, NGSP, CE
    Price : USD7,000.00-12,000.00/Unit
    Supply Ability : 100 Units/Day
    Delivery Time : 15-20 working days
    • Product Details
    • Company Profile

    Fasting Diagnostic HPLC HbA1c Analyzer Fully Automated 5uL In Whole Blood Mode

    Analyzer for HbA1c Testing HPLC Method Fasting Diagnostic Hba1c Fully Automated Analyzer


    Intended use
    The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.
    Principle
    Using high performance liquid chromatography (HPLC), the stationary phase used is a weakly acidiccation exchanger. Glycosylation of hemoglobin will result in the loss of cations on the surface of hemoglobin without being charged, and non glycosylated hemoglobin has a positive charge. According to the different charged properties of hemoglobin, eluents with different pH values and ionic strengths are used sequentially, and several hemoglobin components including HbA1c are separated by high performance liquid chromatography. Each component is detected by a single wavelength colorimeter, and the detected data is processed by a computer to calculate the percentage content of HbA1c in the total hemoglobin.

    Specification


    InstrumentManufacturerLanovation
    Manufacture placeChina
    ModelLD-560
    Dection informationPrincipleHPLC
    Detection methodDual wavelengh colorimetry
    Wavelength420nm
    Test time90 Seconds
    Test Speed throughtput40 samples per hour
    Sample informationSample typesWhole blood or Pre-diluent sample
    Test blood volume5μL in whole blood mode
    150μL in pre-diluted mode
    Sample capacity20 samples
    Sample loading methodContinuous automatic sample loading
    MixerNo, but probe mixing samples
    Reagent and other consumbleColumn test quantity3000
    Reagent pack600T(Reagent)/ 3000T(Column) separate
    Eluent2
    Operation and character informationOperation screen10 inch Full color LCD display
    Data storage5000
    Built-in Thermal PrinterYes
    Performance informationCV<2%
    Test range3.0%~18.0%
     
    Package Information
    Dimensions378(L) ×380(W)×510(H)mm
    Weight28kg

    Warning

    • This instrument is only intended for use by the physicians or qualified professionals trained by Labnovation or Labnovation’s agents.
    • This instrument can only carry out the instrument inspection service or any spare parts service provided by Labnovation or Labnovation’s agents.
    • It is important for the hospital or organization that uses this instrument to execute a reasonable service/maintenance plan. Neglect of service/maintenance may cause instrument breakdown or injury to human health.
    • If any problem occurs, please perform the troubleshooting procedures in accordance with Chapter 8. If the problem still exists, please contact the Labnovation service department for help.
    • Please make sure that this analyzer is used under the conditions specified in the instruction manual. The incorrect instruction may result in abnormal operation of the analyzer, unreliable measuring results, and possibly cause damage to parts of the analyzer or even personal injury.
    • The instrument should be inspected strictly before unpacking. In order to avoid breakage in transportation, the instrument is carefully packaged. When receiving the analyzer, please carefully check if there is physical damage in the packaging. If the packaging is damaged, please contact our services personnel.


    Reagents and Consumables

    The analyzer is recommended to be used in conjunction with the Glycosylated Hemoglobin Test Reagent Kit (high performance liquid chromatography (HPLC method)) produced by our company, which includes the following components:
    Eluent A/Eluent B/Eluent C(Variant Mode)Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non glycated hemoglobin.
    Hemolysis ReagentUsed to dissolve red blood cells and release hemoglobin.
    Chromatography ColumnUsed for separation and elution of glycosylated hemoglobin and non glycated.
    Hemoglobin FilterUsed to initially filter the sample after hemolysis.
    Paper RollsPrints a report of the test results.
    Fasting Diagnostic HPLC HbA1c Analyzer Fully Automated 5uL In Whole Blood Mode

    Exhibition


    Fasting Diagnostic HPLC HbA1c Analyzer Fully Automated 5uL In Whole Blood Mode

    Quality Fasting Diagnostic HPLC HbA1c Analyzer Fully Automated 5uL In Whole Blood Mode for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Labnovation Technologies, Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)