    Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample

    Ask Lasest Price
    Brand Name : LABNOVATION
    Model Number : LD-100
    Certification : IFCC, NGSP, CE
    Price : Negotiation
    Payment Terms : D/A, D/P, T/T
    Supply Ability : 100/Day
    Delivery Time : 15-20 working days
    • Product Details
    • Company Profile

    Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample

    LD-100 Analyzer POCT Best Performance IFCC&NGSP Certificated Battery Integrated One Step Use HbA1c Analyzer


    Intended Use

    Labnovation HbA1c Analyzer LD-100 POCT Analyzer is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood which is a semi-automatic instrument used to analyze glycated hemoglobin. LD-100 is small and light, it can be used to detect of HbA1c in medical units at all levels. Fually Automatic system can help the test half work with double results.



    Specifications

    ModelLD-100
    Sample TypeWhole blood
    Sample Volume4ul
    Test TimeLess than 3 minutes
    Data storage7000
    MethodFluorescent Immunoturbidimetry
    Operating Type1-Step Operation, Fully automatic system
    Measurement RangeHbA1c 4.0~15%(NGSP Unit)
    eAG 68-385mg/dl(mmol/l)
    Operating ConditionTemperature:15~35℃
    Humidity:15~80%R.H
    Storage ConditionAnalyzer:10-60℃; Test kit: 2~8℃
    Voltage12VDC-3.33A
    Analytical wave-length510nm and 580nm.
    CertificationNGSP, IFCC
    Working Principles
    HbA1c Analyzer uses the (borate affinity) fluorescent immunoturbidimetry. Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently. The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells. The total concentration of hemoglobin depends on the initial reduced fluorescence signal. Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients. The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

    Reliable

    IFCC calibratorNormalAbnormalNormalAbnormal
    Mean HbA1c%5.49.65.39.2
    CV (%)2.5%1.9%2.4%1.8%

    Performance

    • Result reporting unit

    Glycated hemoglobin (HbA1c) is reported by default in IFCC units (mmol/mol) and NGSP units (%).

    • Accuracy

    The accuracy is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.

    • Precision

    Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.

    • Linearity

    In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.

    • Stability

    Within 8 hours after the instrument is turned on and stable, the same normal sample is tested, and POCT HbA1c Analyzer V1.0 2 the relative deviation of the test results is not more than ±3%.


    Certificate

    Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood SampleBattery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample


    Attention

    The HbA1c Analyzer meets the emission and immunity requirements specified in the relevant Section of GB/T 18268.26, as shown in the table below.

    • Users have the responsibility to ensure the electromagnetic compatibility environment of the equipment, so that the equipment can work properly.
    • It is recommended that the electromagnetic environment be evaluated before the equipment is used.