Sign In | Join Free | My himfr.com
Home > POCT HbA1c Analyzer >

LD-100 Hematology Detection Analyzer Medical One Step Hemoglobin A1c Analyzer

    Buy cheap LD-100 Hematology Detection Analyzer Medical One Step Hemoglobin A1c Analyzer from wholesalers
     
    Buy cheap LD-100 Hematology Detection Analyzer Medical One Step Hemoglobin A1c Analyzer from wholesalers
    • Buy cheap LD-100 Hematology Detection Analyzer Medical One Step Hemoglobin A1c Analyzer from wholesalers
    • Buy cheap LD-100 Hematology Detection Analyzer Medical One Step Hemoglobin A1c Analyzer from wholesalers

    LD-100 Hematology Detection Analyzer Medical One Step Hemoglobin A1c Analyzer

    Ask Lasest Price
    Brand Name : LABNOVATION
    Model Number : LD-100
    Certification : IFCC, NGSP, CE
    Price : Negotiation
    Payment Terms : D/A, D/P, T/T
    Supply Ability : 100/Day
    Delivery Time : 10 work day
    • Product Details
    • Company Profile

    LD-100 Hematology Detection Analyzer Medical One Step Hemoglobin A1c Analyzer

    HbA1c Analyzer LD-100 Hematology Detection Analyzer Medical Use HbA1c Analyzer


    Intended Use

    This instrument is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood.

    Specifications

    ModelLD-100
    MethodBoronate Affinity
    Operating Type1-Step, fully automatic
    Measurement TimeLess than 3 minutes
    Sample TypeWhole blood
    Measurement RangeHbA1c 4.0~15%(NGSP Unit)
    eAG 68-385mg/dl(mmol/l)
    Operating ConditionTemperature:15~35℃
    Humidity:15~80%R.H
    Dimensions220(w)x150(L)x120(H)mm
    Shelf-Life of Test Kit9 months
    Weight800gs
    Storage ConditionAnalyzer:10-60℃; Test kit: 2~8℃
    Voltage12VDC-3.33A

    PRINCIPLE
    HbA1c Analyzer uses the (borate affinity) fluorescent immunoturbidimetry. Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently. The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.


    Performance Parameters

    • Accuracy:The relative deviation of the determination results of the analyzer should be within the range of ±8%.
    • Precision:Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.
    • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.
    • Stability:Within 8 hours after the instrument is turned on and stable, the same normal sample is tested, and the relative deviation of the test results is not more than ±3%.

    Feature

    • One-step Operation
    • Boronate Affinity
    • Battery Integrated
    • Portable, Compact
    • Cv<3%, Excellent Correlation With HPLC
    • RFID For Batch Management
    • Color touch screen
    • External printer (Blue-tooth)
    • USB Port, LIS Support

    Reliable

    IFCC calibratorNormalAbnormalNormalAbnormal
    Mean HbA1c%5.49.65.39.2
    CV (%)2.5%1.9%2.4%1.8%

    Use Step

    • Place cartridge in analyzer
    • Push bead into reagents
    • Insert sample into cartridge


    Certificated


    Quality LD-100 Hematology Detection Analyzer Medical One Step Hemoglobin A1c Analyzer for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Labnovation Technologies, Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)