Sign In | Join Free | My himfr.com
Home > IgG IgM Rapid Test Kits >

Universal Rapid Dengue IgM IgG Test Kit For IN VITRO Diagnose

    Buy cheap Universal Rapid Dengue IgM IgG Test Kit For IN VITRO Diagnose from wholesalers
     
    Buy cheap Universal Rapid Dengue IgM IgG Test Kit For IN VITRO Diagnose from wholesalers
    • Buy cheap Universal Rapid Dengue IgM IgG Test Kit For IN VITRO Diagnose from wholesalers
    • Buy cheap Universal Rapid Dengue IgM IgG Test Kit For IN VITRO Diagnose from wholesalers

    Universal Rapid Dengue IgM IgG Test Kit For IN VITRO Diagnose

    Ask Lasest Price
    Brand Name : LABNOVATION
    Model Number : LQ-000103
    Certification : ISO13485, ISO9001,
    Price : US$0.4-0.8/pcs
    Payment Terms : D/A, D/P, T/T
    Supply Ability : 500000/Day
    Delivery Time : 5-7 work day
    • Product Details
    • Company Profile

    Universal Rapid Dengue IgM IgG Test Kit For IN VITRO Diagnose

    Rapid Antibody Test Kit IgG/IgM Antibody Testing Dengue Antibody Test 25 Tests Professional Use


    Intenden Use
    The Dengue IgG/IgM Antibody Test Kit is a rapid chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) to dengue virus in serum/plasma/whole blood to aid in the diagnosis of Dengue viral infection.
    Specifications

    Test ItemDengue IgM/IgG Antibody Rapid Test Kit
    Sample TypeSerum, Plasma, Whole Blood
    Sample Volume1 Full Drop (30 μl)
    Package Size25 Tests/Box
    Product Shelf Life24 Months
    Test SpeedWithin 15 minutes
    Storage ConditionStore 2-30℃
    Humidity≤60%

    Product Features

    Accuracy: High Sensitivity, Specificity and Total Accuracy

    Flexible: Can use serum, plasma and whole blood

    Simple: Sinple operation, one step to use

    Fast: Quck recation, read the result within 15 minutes

    Advantages

    • Simple: simply add specimen and dilution into sample well.
    • Rapid: results come out at 10-15 minutes
    • Visually interpreted: dont need any equipment
    • Stable: Long shelf life


    Main Components

    • 25 Test Cassettes
    • 25 Disposable Pipettes
    • 1 Specimen Buffer
    • 1 Instruction Manual

    Analytical Resualts

    ItemIgGIgM
    Specificity98.46%98.44%
    Sensitivity96.19%95.37%
    Accuracy97.67%97.33%

    Use Step

    • Take off the outer packing, put the cassette onto the desk with the sample window up.
    • Drop 1 drop (30μl) of serum/plasma/whole blood vertically into the sample well of cassette. Add about 2 drops (80-100μl) of specimen buffer into the sample well of cassette.
    • Observe the test results immediately within 15-20 minutes, the result is invalid after 20 minutes.

    Interpreation Of Result

    • POSITIVE:
    1. Two distinct red lines appear. One line should be in the control region (C) and another line should be in the IgG test region (T1), indicating the Dengue IgG positive.
    2. Two distinct red lines appear. One line should be in the control region (C) and another line should be in the IgM test region (T2), indicating the Dengue IgM positive.
    3. Three distinct red lines appear in the control region (C), the IgG test region (T1) and the IgM test region (T2), indicating the Dengue IgG and Dengue IgM positive.
    • NEGATIVE: One red line appears in the control region(C). No apparent red or pink line appears in the test region (T1 and T2).
    • INVALID: No red bands appear or control line fails to appear, indicating that the operator error or reagent failure.


    Precautions

    • For IN VITRO diagnose only.
    • Do not use after the expiration date.
    • The test result is invalid over 20 minutes.
    • The strength of the quality control line does not indicate the quality problem of the reagent, a test result that is clearly visible demonstrates the reagent is effective.
    • All samples and reagents should be considered potentially hazardous and handled in the same manner as an infectious agent after use.
    • Do not use other kinds of quality control sample to test the reagent. Components of different batches cannot be exchanged for use to avoid erroneous results.

    Other Informations

    • The results of the reagent are only for clinical reference, which is not the only basis for clinical diagnosis and treatment.
    • Negative result may occur when detecting short-term infected samples or some second time infected samples, indicating that the specific antibodies of Dengue IgM does not exist or the concentration is below the detection limit. Some patients may not produce enough antibodies to be detected in their body within 7 - 10 days, it may show negative results. For some patients, if the Dengue infection is still suspected, they need to do a new Dengue rapid test 3-4 days later.

    FAQ

    • MOQ?

    MOQ is 10000 pcs

    • How can I get a price of needed product?

    Please give your exactly specs details to us. We can give you a sample and price according to your specification

    • Shippment?

    We choose Air cargo or Ocean cargo.

    • Delivery date?

    After order confirmed,we will arrange your order immediately,and offer you an estimated delivery date.

    • Payment Method?

    Business to business account.

    • Are you a manufacturer or trading company?

    We are manufacturer.



    Quality Universal Rapid Dengue IgM IgG Test Kit For IN VITRO Diagnose for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Labnovation Technologies, Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category: