Sign In | Join Free | My himfr.com
Home > Saliva Antigen Test Kit >

IVD SARS-CoV-2 20 Tests Professional ART Self Test Kit ISO9001

    Buy cheap IVD SARS-CoV-2 20 Tests Professional ART Self Test Kit ISO9001 from wholesalers
     
    Buy cheap IVD SARS-CoV-2 20 Tests Professional ART Self Test Kit ISO9001 from wholesalers
    • Buy cheap IVD SARS-CoV-2 20 Tests Professional ART Self Test Kit ISO9001 from wholesalers
    • Buy cheap IVD SARS-CoV-2 20 Tests Professional ART Self Test Kit ISO9001 from wholesalers

    IVD SARS-CoV-2 20 Tests Professional ART Self Test Kit ISO9001

    Ask Lasest Price
    Brand Name : LABNOVATION
    Model Number : LX-401603
    Certification : ISO13485,ISO9001,CE
    Price : Negotiation
    Payment Terms : T/T, D/A, D/P
    Supply Ability : 500000/Day
    Delivery Time : 5-7 work day
    • Product Details
    • Company Profile

    IVD SARS-CoV-2 20 Tests Professional ART Self Test Kit ISO9001

    Rapid Test Kit SARS-CoV-2 Antigen Saliva Rapid Test Kit 20 Tests For Professional Use Antigen Rapid Test Kit

    Intend Use

    This rapid test kit is qualitative detection of SARS-CoV-2 antigen in saliva sample which can be used to detection of SARS-CoV-2 antigen in human saliva samples from novel coronavirus suspected person with symptoms within 9 days from onset. The test result can be used for early triage and rapid management of suspected populations, but it cannot be used as diagnosis basis of SARS-CoV-2 infection. Further nucleic acid detection should be carried out for suspected population whose antigen test result is positive or negative.


    Product Details

    ItemValue
    Model NumberLX-401603
    Type20 Tests/ Kit
    Quality CertificationCE, MSDS
    Safty StandardISO13485, ISO9001
    Specimen TypeSaliva
    Sample volume3 Full drops
    specificity99.00%
    sensitivity94.29%
    Total Accuracy98.02%


    Product Feature

    • Fast result as soon as 10-15 minutes
    • Simple, time-saving procedure
    • Little specimen, only few saliva sample
    • All necessary reagents provided, no extra equipment needed
    • High sensitivity and specificity

    Test Principle

    This kit is an immunochromatography assay. According to the gold immunochromatographic test principle, double antibody sandwich method was used to detect SARS-CoV-2 nucleocapsid antigen in the samples.

    • Main Components
    • 20 Test Cassettes
    • 20 Saliva Collectors With Collection Tubes
    • 20 Sample Extraction Buffer
    • 1 Tube stand
    • 1 Package Insert


    Sample Collection

    • 30 minutes before sampling, please do not eat, smoke, drinking alcohol or drinks.
    • Place the tip of tongue against the upper or lower tooth root to enrich saliva, and then swallow saliva to the throat without ingesting saliva to esophagus, followed by returning saliva to the mouth. Repeat the process for 5 times.
    • The sample should not be inactivated.

    Use Step

    • Open the cap of the collection tube and istall saliva collector.
    • Put the collection tube with saliva collector close to lips and let the saliva flow into the collection tube. Tje volum of saliva needs to be half of 0.5 scal mark(0.25).
    • Screw the sample extraction buffer carefully.

    • Add all sample extration buffer to the collection tube. Discard the saliva collector, tighten the cap onto the specimen collection tube.
    • Shake the specimen collection tube at least three time vigorously to mix the saliva and the extraction buffer. Squeeze bottom of the collection tube ensure the saliva is thoroughly mixed.
    • Add 3 full drops of the solution to the sample well(S). Read the result at 15 minutes. Do not interpret the result after 20 minutes.


    Result Interpretation

    • POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

    • NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit.

    • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.



    Virus Sources

    Global high frequency mutationAlpha / B.1.1.7(U.K.)Beta I B.1.351(South Africa)
    Gemma I P.1(Brazil)Kappa I B.1.617.1(India)Delta I B.1.617.2(India)
    C.37,ectAlpha I B.1.17(U.K.)B.1.36.16.etc
    A.2.5,etcA.23.1Alpha I B.1.17(U.K.)
    B.1.1.33.etcC.1.1.etc.Etc.


    Certificate

    Quality IVD SARS-CoV-2 20 Tests Professional ART Self Test Kit ISO9001 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Labnovation Technologies, Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)