LD-100 POCT HbA1c Analyzer Real Time Detection Protable HbA1c Analyzer

    Buy cheap LD-100 POCT HbA1c Analyzer Real Time Detection Protable HbA1c Analyzer from wholesalers
     
    Buy cheap LD-100 POCT HbA1c Analyzer Real Time Detection Protable HbA1c Analyzer from wholesalers
    • Buy cheap LD-100 POCT HbA1c Analyzer Real Time Detection Protable HbA1c Analyzer from wholesalers
    • Buy cheap LD-100 POCT HbA1c Analyzer Real Time Detection Protable HbA1c Analyzer from wholesalers

    LD-100 POCT HbA1c Analyzer Real Time Detection Protable HbA1c Analyzer

    Ask Lasest Price
    Brand Name : LABNOVATION
    Model Number : LD-100
    Certification : IFCC, NGSP, CE
    Price : Negotiation
    Payment Terms : D/A, D/P, T/T
    Supply Ability : 100/Day
    Delivery Time : 10 work day
    • Product Details
    • Company Profile

    LD-100 POCT HbA1c Analyzer Real Time Detection Protable HbA1c Analyzer

    HbA1c Analyzer LD-100 POCT HbA1c Analyzer Protable Real-Time Detection HbA1c Analyzer

    Intended Use

    LD-100 POCT HbA1c Analyzer is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood. Which is a semi-automatic instrument used to analyze glycated hemoglobin and it's suitable for the detection of HbA1c in medical units at all levels.

    Specifications

    ModelLD-100
    MethodBoronate Affinity
    Operating Type1-Step, fully automatic
    Measurement TimeLess than 3 minutes
    Sample TypeWhole blood
    Sample Volume4ul
    Measurement RangeHbA1c 4.0~15%(NGSP Unit)
    eAG 68-385mg/dl(mmol/l)
    Data storage7000
    Operating ConditionTemperature:15~35℃
    Humidity:15~80%R.H
    Storage ConditionAnalyzer:10-60℃; Test kit: 2~8℃
    Voltage12VDC-3.33A
    Device categoryFixed


    PRINCIPLE

    • Uses the (borate affinity) fluorescent immunoturbidimetry
    • Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
    • The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
    • The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
    • Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
    • The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

    Feature

    • One-step Operation, simple use process easy to test HbA1c
    • Protable, easy to carry
    • Fast tets speed, Real-time detection
    • Battery Integrated
    • Portable, Compact
    • Cv<3%, Excellent Correlation With HPLC
    • RFID For Batch Management
    • Color touch screen
    • External printer (Blue-tooth)
    • USB Port
    • LIS Support

    Reliable

    IFCC calibratorNormalAbnormalNormalAbnormal
    Mean HbA1c%5.49.65.39.2
    CV (%)2.5%1.9%2.4%1.8%

    Use Step

    • Place cartridge in analyzer
    • Push bead into reagents
    • Insert sample into cartridge


    Performance Parameters

    • Accuracy:The accuracy is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
    • Result reporting unit:Glycated hemoglobin (HbA1c) is reported by default in IFCC units (mmol/mol) and NGSP units (%).
    • Precision:Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.
    • Appearance:The appearance of the instrument is neat and clean, and there is no obvious peeling, abrasion, disbonded coating and dirt on the surface coating; The nameplate and logo should be clear. All fasteners should not be loosened. Various adjusting elements can rotate flexibly and function normally. Readouts should be clear on the display screen.
    • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.
    • Stability:Within 8 hours after the instrument is turned on and stable, the same normal sample is tested, and the relative deviation of the test results is not more than ±3%.
    • Functions of the analyzer:The function of report output in English; Abnormal alarm function.
    • Permission: The authority is the first-level authority, and the login authority is the first-level authority

    Certificated


    Quality LD-100 POCT HbA1c Analyzer Real Time Detection Protable HbA1c Analyzer for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Labnovation Technologies, Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)