    LD-560 HbA1c Rapid Test Analyzer Big Capacity Fully Automatic HbA1c Analyzer

    Ask Lasest Price
    Brand Name : LABNOVATION
    Model Number : LD-560
    Certification : IFCC, NGSP, CE
    Price : US$5000-12000/Piece
    Payment Terms : D/A, D/P, T/T
    Supply Ability : 100/Day
    Delivery Time : 5-7 work day
    • Product Details
    • Company Profile

    LD-560 HbA1c Rapid Test Analyzer Big Capacity Fully Automatic HbA1c Analyzer

    LD-560 HbA1c Rapid Test Analyzer Big Capacity Fully Automatic HbA1c Analyzer


    Intended Use

    The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.


    Specifications

    ModelLD-560
    MethodHPLC (High Performance Liquid Chromatography)
    ParametersHbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional)
    Test Speed90 seconds per test
    Wavelength420nm
    Sample TypeWhole Blood, Pre-diluted blood
    Autoloader Capacity20 tubes
    Reagents KitEluent A, Eluen B, Hemolysis, Chromatography Column
    PrecisionCV<2%
    Column Capacity3000 tests
    Report Range3-18%
    Working ConditionTemperature: 15-30℃, Humidity: 30-85%
    Voltage100-240VA
    Frequency50/60Hz
    Dimensions378mm×380mm×510mm

    Feature

    • Proven golden standard method for HbA1c testing
    • Large size touch screen for friendly interface
    • Most cost-effective

    PRINCIPLE
    Using high performance liquid chromatography (HPLC), the stationary phase used is a weakly acidic cation exchanger. Glycosylation of hemoglobin will result in the loss of cations on the surface of hemoglobin without being charged, and non-glycosylated hemoglobin has a positive charge. According to the different charged properties of hemoglobin, eluents with different pH values and ionic strengths are used sequentially, and several hemoglobin components including HbA1c are separated by high performance liquid chromatography. Each component is detected by a single-wavelength colorimeter, and the detected data is processed by a computer to calculate the percentage content of HbA1c in the total hemoglobin.


    Performance Parameters
    Accuracy: The accuracy is tested with reference materials as samples, and the relative deviation of the test results should be within ±5%.
    Repeatability: For samples with a test concentration of 4%-6%, the sample coefficient of variation (CV) of the test results is not greater than 2.0%.
    Linear range: Within the range of 3%-18% of glycosylated hemoglobin, the linear correlation coefficient R value of the test results should not be less than 0.9900.
    Stability: Within 8 hours after the analyzer is turned on and stabilized, the same normal sample is tested, and the relative deviation of the test results is not more than ±3.0%.
    Carrying pollution: The carrying pollution rate of the analyzer should not be greater than 2.0%.

    Certificated


    Quality LD-560 HbA1c Rapid Test Analyzer Big Capacity Fully Automatic HbA1c Analyzer for sale