Sign In | Join Free | My himfr.com
Home > Hematology Analyzer Reagents >

50L Cell Dyn Ruby Hematology Analyzer Reagents Medical Lab Reagents

    Buy cheap 50L Cell Dyn Ruby Hematology Analyzer Reagents Medical Lab Reagents from wholesalers
     
    Buy cheap 50L Cell Dyn Ruby Hematology Analyzer Reagents Medical Lab Reagents from wholesalers
    • Buy cheap 50L Cell Dyn Ruby Hematology Analyzer Reagents Medical Lab Reagents from wholesalers
    • Buy cheap 50L Cell Dyn Ruby Hematology Analyzer Reagents Medical Lab Reagents from wholesalers

    50L Cell Dyn Ruby Hematology Analyzer Reagents Medical Lab Reagents

    Ask Lasest Price
    Brand Name : LABNOVATION
    Certification : ISO13485, ISO9001,CE
    Price : US$8-12/Pieces
    Payment Terms : D/A, D/P, T/T
    Supply Ability : 500000/Day
    Delivery Time : 10 work day
    Model Number : L-03H79-01
    • Product Details
    • Company Profile

    50L Cell Dyn Ruby Hematology Analyzer Reagents Medical Lab Reagents

    Hematology Analyzer Reagents Hematology Reagent For CD3200 Analyzers High Quality Rreagents


    Intended Use

    To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on ABBOTT CELL-DYN Ruby hematology analyzers. This product is for In Vitro Diagnostic Use only.

    Procedures
    • Using the function keys press the following menus:

    MAIN-SPECIAL PROTOCOLS-REAGENT RESERVOIRE-EMTY DILUENT

    • Remove the reagent inlet tube from the Diluent.
    • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
    • Put the reagent tubes into the boxes and/or bottles of Labnovation reagents.
    • Using the function keys press the following menu:

    FILL DILUENT

    This step will fill the reagent system with Labnovation reagent.

    • Repeat steps 1-5 with Lyse and Sheath.
    • Run at least 5 backgrounds. Check for the acceptable values.
    • Run all three levels of a dedicated commercial control. Check for the acceptable values.
    • Recalibrate the unit if necessary. (MAIN-CALIBRATION-ENTER-FACTOR)
    Precaution
    • Re-calibration is recommended when changing the origin of the reagents.
    • It is not recommended using different brands of solutions together on one unit of analyzer.
    • Do not ingest. Avoid contact with skin and eyes.
    • Skin contact: Flush with plenty of water.
    • Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
    • This kit is for professionals and in vitro diagnostic use only.
    • Never put distilled water on the analyser (except clean for shipping menu), otherwise the pneumatic unit can be damaged seriously.

    Specification

    L-03H79-01Diluent/Sheath20 L
    L-03H78-38WBC Lyse3.8 L
    L-03H80-01HGB/NOC Lyse3.8 L
    33-40-E00133-40-E00150 ML×2

    KIT COMPOSITION

    Diluent/Sheath

    NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0%

    WBC LyseSurfactant, Lauroyl Sulfate, Ammonium salt and Buffer
    HGB/NOC Lyse

    Quaternary Ammonium Salt<10%, Hydroxylamine Salt<3.5%

    EZ-CleanerSubtilisin<5.0%

    APPLICABLE INSTUMENT

    • For use with CD3200 hematology analyzers.
    Advantage
    • One source for all brands of analyzer
    • Reagents for both 3-parts and 5-parts
    • Ready-to-use final products and bulk OEM reagents
    • ISQ13485:2003 and ISO9001:2008 certified
    • CE marked, FDA cleared
    • Well-established brand used by thousands of lab in 95 countries
    • High quality, high performance and high fidelity of correlations with original brand.

    Storage


    • Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.
    • The open vial life of the product is 30/60 days. Unused reagents should be discarded after 30/60 days. Do not mix residual with a new carton.

    Quality 50L Cell Dyn Ruby Hematology Analyzer Reagents Medical Lab Reagents for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Labnovation Technologies, Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)