Sign In | Join Free | My himfr.com
Home > Hematology Analyzer Reagents >

IVD Labnovation Hematology Analyzer Reagents For Erma Pce-210

    Buy cheap IVD Labnovation Hematology Analyzer Reagents For Erma Pce-210 from wholesalers
     
    Buy cheap IVD Labnovation Hematology Analyzer Reagents For Erma Pce-210 from wholesalers
    • Buy cheap IVD Labnovation Hematology Analyzer Reagents For Erma Pce-210 from wholesalers
    • Buy cheap IVD Labnovation Hematology Analyzer Reagents For Erma Pce-210 from wholesalers

    IVD Labnovation Hematology Analyzer Reagents For Erma Pce-210

    Ask Lasest Price
    Brand Name : LABNOVATION
    Payment Terms : D/A, D/P, T/T
    Delivery Time : 5-7 work day
    • Product Details
    • Company Profile

    IVD Labnovation Hematology Analyzer Reagents For Erma Pce-210

    Hematology Analyzer Reagents Hematology Reagent For Erma Pce-210 Analyzers High Quality


    Intended Use

    The hematology ana;yzer reagents to be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Erma PCE-210 hematology analyzers. This product is for In Vitro Diagnostic Use only.


    Specification

    80-10-020DILUENT CM20L
    80-30-005LYSE CM500mL
    80-40-001CLEANER CM1L

    Kit Composistion

    DILUENT CMNaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0%
    LYSE CMQuaternary Ammonium Salt<10%, Sodium Lauryl Sulfate<1.5%
    CLEANER CM

    Buffer<0.3%, Proteolytic Enzyme<0.2%


    Applicable Insteument

    For use with Erma PCE-210 hematology analyzers.


    Procedures

    • Remove all the reagent aspiration tubes from the currently used reagent boxes or bottles.
    • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
    • Put the tubes into the LABNOVATION reagent boxes or bottles.
    • Run at least 50 backgrounds. Check for the acceptable values. At first high background counts can be seen, that should lower to normal after a few runs.
    • Run all three levels of a dedicated commercial control. Check for the acceptable values.
    • Recalibrate the unit if necessary.

    Storage

    Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.

    The open vial life of the product is 30 or 60 days (according to the table above). Unused reagents should be discarded after period of validity. Do not mix residual with a new carton.


    Precautions

    1. Re-calibration is recommended when changing the origin of the reagents.
    2. It is not recommended using different brands of solutions together on one unit of analyzer.
    3. Do not ingest. Avoid contact with skin and eyes.
    4. Skin contact: Flush with plenty of water.
    5. Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
    6. This kit is for professionals and in vitro diagnostic use only.

    Quality IVD Labnovation Hematology Analyzer Reagents For Erma Pce-210 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Labnovation Technologies, Inc.
    *Subject:
    *Message: