OEM ODM Dengue NS1 Antigen Test Kit IgG IgM Combo Rapid Test Kit

    Buy cheap OEM ODM Dengue NS1 Antigen Test Kit IgG IgM Combo Rapid Test Kit from wholesalers
     
    Buy cheap OEM ODM Dengue NS1 Antigen Test Kit IgG IgM Combo Rapid Test Kit from wholesalers
    • Buy cheap OEM ODM Dengue NS1 Antigen Test Kit IgG IgM Combo Rapid Test Kit from wholesalers
    • Buy cheap OEM ODM Dengue NS1 Antigen Test Kit IgG IgM Combo Rapid Test Kit from wholesalers

    OEM ODM Dengue NS1 Antigen Test Kit IgG IgM Combo Rapid Test Kit

    Ask Lasest Price
    Brand Name : LABNOVATION
    Model Number : LQ-000101
    Certification : ISO13485, ISO9001,
    Price : US$1.0-1.3/pcs
    Payment Terms : D/A, D/P, T/T
    Supply Ability : 500000/Day
    Delivery Time : 5-7 work day
    • Product Details
    • Company Profile

    OEM ODM Dengue NS1 Antigen Test Kit IgG IgM Combo Rapid Test Kit


    Rapid Antigen And Antibody Test Kit Dengue NS1/IgG/IgM Combo Rapid Test Kit 25 Tests Professionla Use Rapid Test Kit


    Intenden Use
    Dengue NS1 Antigen & IgG/IgM Antibody Rapid Test Kit is a rapid Immunochromatography for the qualitative detection of antibodies (IgM and IgG) and dengue virus NS1 antigen to dengue virus in serum/plasma/whole blood to aid in the diagnosis of Dengue viral infection.
    Specifications

    NameDengue NS1 Antigen & IgM/IgG Antibody Rapid Test Kit
    NoLQ-000101
    Sample TypeSerum, Plasma, Whole Blood
    Sample VolumeNS1:3 Drops(80-100μ), IgG/IgM:1 Drop(30μl)
    Package Size25 Tests/Kit
    Product Shelf Life24 Months
    Test SpeedWithin 15 minutes
    Storage ConditionStore 2-30℃

    Product Features

    • Rapid testing for antigen within 15 minutes
    • Facilitates patient treatment decisions quickly
    • Simple, time-saving procedure
    • All necessary reagents provided & no equipment
    • needed High sensitivity and specifificity


    Main Components

    • 25 Test Cassettes
    • 25 Disposable Pipettes
    • 1 Specimen Buffer
    • 1 Instruction For Use

    Material Needed But Not Provided

    • Specimen Collection Containers
    • Centrifuge (for serum/plasma sample)
    • Timer

    Use Step

    • Take off the outer packing, put the panel onto the desk with the sample window up.
    • NS1: Drop 3 drops (80-100μl) of serum/plasma/whole blood vertically into the sample well of NS1. If the whole blood sample is thick, add about 1 drop (40-50μl) of specimen buffer into the sample well of NS1
    • IgG/IgM: Drop 1 drop (30μl) of serum/plasma/whole blood vertically into the sample well of IgG/IgM, add about 2 drops (80-100μl) of specimen buffer into the sample well of IgG/IgM.
    • Observe the test results immediately within 15-20 minutes, the result is invalid after 20 minutes.

    Interpreation Of Result

    • For Dengue NS1:
    1. POSITIVE: Two distinct red lines appear. One line should be in the control region (C) and the other line should be in the test region (T).
    2. NEGATIVE: One red line appears in the control region(C). No apparent red or pink line appears in the test region (T).
    3. INVALID: No red lines appear or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.
    • For Dengue IgG/IgM:

    1. POSITIVE: Two distinct red lines appear. One line should be in the control region (C) and another line should be in the IgG test region (G), indicating the Dengue IgG positive.
    2. POSITIVE: Two distinct red lines appear. One line should be in the control region (C) and another line should be in the IgM test region (M), indicating the Dengue IgM positive.
    3. POSITIVE: Three distinct red lines appear in the control region (C), the IgG test region (G) and the IgM test region (M), indicating the Dengue IgG and Dengue IgM positive.
    4. NEGATIVE: One red line appears in the control region(C). No apparent red or pink line appears in the test region (G and M).
    5. INVALID: No red bands appear or control line fails to appear, indicating that the operator error or reagent failure.

    Analytical Resualts

    ItemIgGIgMNS1
    Specificity98.46%98.44%99.02%
    Sensitivity96.19%95.37%97.92%
    Accuracy97.67%97.33%98.67%

    Precautions

    • For IN VITRO diagnose only.
    • Do not use after the expiration date.
    • The test result is invalid after 20 minutes.
    • The strength of the quality control line does not indicate the quality problem of the reagent, a test result that is clearly visible demonstrates the reagent is effective.
    • All samples and reagents should be considered potentially hazardous and handled in the same manner as an infectious agent after use.
    • Do not use other kinds of quality control sample to test the reagent. Components of different batches cannot be exchanged for use to avoid erroneous results
    • The continued existed or not existed of antibodies cannot be used to determine if the treatment is succeeded or not.
    • The best time for dengue testing is 6 ~ 14 days after the symptom of fever.
    • Do not use other kinds of quality control sample to test the reagent. Components of different batches cannot be exchanged for use to avoid erroneous results

    FAQ

    • MOQ?

    MOQ is 10000 pcs

    • Shippment?

    We choose Air cargo or Ocean cargo.

    • Delivery date?

    It will depend on your order quantities. We will confirm with you after you placed the order.

    • Payment Method?

    Business to business account.

    • Do you support OEM/ODM order?

    Of couse, we support OEM/ODM order.

    • Are you a manufacturer or trading company?

    We are manufacturer.

    • After-sales Service

    Any questions or needs you can contact us online / by e-mail, ect. we will get back to you within 24 hours.