    Labnovation LD-560 HbA1c Analyzer HPLC System For HbA1c Testing Dual Mode With NGSP&IFCC Certificated

    Ask Lasest Price
    Brand Name : LABNOVATION
    Model Number : LD-560
    Certification : IFCC, NGSP, CE
    Price : US$5000-12000/Piece
    Payment Terms : D/A, D/P, T/T
    Supply Ability : 100 Units/Day
    Delivery Time : 5-7 work day
    • Product Details
    • Company Profile

    Labnovation LD-560 HbA1c Analyzer HPLC System For HbA1c Testing Dual Mode With NGSP&IFCC Certificated

    Labnovation LD-560 HbA1c Analyzer HPLC System For HbA1c Testing Dual Mode With NGSP&IFCC Certificated


    Intended Use


    The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.


    Specification


    ModelLD-560
    MethodHPLC
    ParametersHbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional)
    Test Speed90 seconds per test
    Reagents kitEluent A, Eluent B, Hemolysis
    Autoloader Capacity20 tubes
    PrecisionCV<2%
    Dimension378(L) ×380(W)×510(H)mm
    Weight28kg

    Labnovation LD-560 HbA1c Analyzer HPLC System For HbA1c Testing Dual Mode With NGSP&IFCC Certificated


    Labnovation LD-560 HbA1c Analyzer HPLC System For HbA1c Testing Dual Mode With NGSP&IFCC Certificated


    Full automatic smart system


    • One click start testing
    • Automatic sample type recognition
    • Automatic testing mode switch
    • Automatic scanning of barcode

    • Autoloader for 20 tubes

    • Easy to change reagents

    Operation Preparation


    Before operating this analyzer, please read the operation manual carefully to avoid malfunction or damage.

    If the analyzer is used in a manner not specified by the manufacturer, the protection provided by the analyzer may be destroyed.

    Before turning on the analyzer, the operator must check the following requirements to ensure that the system is ready.

    (1) Check the remaining amount of reagents

    Check whether the remaining amount of eluent A, eluent B, eluent C and hemolysis agent is sufficient.

    (2) Check the waste liquid barrel

    Check whether the waste liquid barrel has been emptied before starting the analyzer every day.

    (3) Check the liquid tubes and power supply

    Check whether the tubes of reagent and waste liquid are bent and whether the connections are reliable.

    Check the analyzer for fluid leakage.

    Check whether the power plug of the analyzer is securely inserted into the power socket.

    (4) Check the printer

    Check whether the paper roll is sufficient and whether it is installed in correct place.

    Labnovation LD-560 HbA1c Analyzer HPLC System For HbA1c Testing Dual Mode With NGSP&IFCC Certificated


    Certificate


    Attention

    • Please make sure that this analyzer is used under the conditions specified in the instruction manual. The incorrect instruction may result in abnormal operation of the analyzer, unreliable measuring results, and possibly cause damage to parts of the analyzer or even personal injury.
    • The instrument should be inspected strictly before unpacking. In order to avoid breakage in transportation, the instrument is carefully packaged. When receiving the analyzer, please carefully check if there is physical damage in the packaging. If the packaging is damaged, please contact our services personnel.
    • Please always keep it upward when unloading and delivering the instrument. Never tilt or roll the instrument. The foam inside the box can prevent shock to a certain extent during the handling of the instrument. Minimize the vibration during handling. After handling, perform checks and debugging.